詳細(xì)參數(shù)
品牌 SIEMENS 規(guī)格型號(hào) 6SL3040-1MA00-0AA0
編號(hào) 6SL3040-1MA00-0AA0 計(jì)量單位 1件
付款方式 面議 參考價(jià)格 3000
價(jià)格單位 人民幣 供貨量 不限
說明書,報(bào)價(jià)手冊(cè)及驅(qū)動(dòng) 暫無(wú)相關(guān)下載 其他資料下載 暫無(wú)相關(guān)下載
產(chǎn)地 德國(guó) 發(fā)貨地 上海

產(chǎn)品詳情

西門子CU320控制單元供應(yīng)

型號(hào):6SL3040-1MA00-0AA0  (西門子CU320-2DP控制單元)

參數(shù):SINAMICS CONTROL UNIT CU320-2 DP WITH PROFIBUS INTERFACE WITHOUT COMPACT FLASH CARD


希殿電氣技術(shù)(上海)有限公司
聯(lián) 系 人:康奎(業(yè)務(wù)經(jīng)理)

聯(lián)系電話:021-60541249

手    機(jī):18621061383

商 務(wù) QQ: 192061030
《銷售態(tài)度》:質(zhì)量保證、誠(chéng)信服務(wù)、及時(shí)到位!
《銷售宗旨》:為客戶創(chuàng)造價(jià)值是我們永遠(yuǎn)追求的目標(biāo)!
《服務(wù)說明》:現(xiàn)貨配送至全國(guó)各地含稅(17%)含運(yùn)費(fèi)!
《產(chǎn)品質(zhì)量》:原裝正品,全新原裝!
《產(chǎn)品優(yōu)勢(shì)》:專業(yè)銷售 薄利多銷 信譽(yù)好,口碑好,價(jià)格低,貨期短,大量現(xiàn)貨,服務(wù)周到!

CU320-2 Control Units

CU320‑2 PN Control Unit

The communication, open-loop and closed-loop control functions for one or more Motor Modules and the Line Module are executed in a CU320‑2 Control Unit. The CU320‑2 Control Unit is essentially designed for multi-axis operation.

CU320‑2 DP Control Unit with BOP20 Basic Operator Panel

The CompactFlash card contains the firmware and beter settings. The CompactFlash card is plugged into the appropriate slot on the CU320‑2 Control Unit.

A CU320‑2 Control Unit can perb the communication, open-loop and closed-loop control functions for several Motor Modules. The computing capacity required increases in proportion to the number of connected Motor Modules and system components and in relation to the dynamic response required. For the CU320‑2 Control Unit, the perbance expansion is necessary for machines with 4 axes or more. The utilization of the CU320‑2 Control Unit can be calculated with the SIZER for Siemens Drives engineering tool.

In addition to the firmware, the CompactFlash Card also contains licensing codes which are required to enable firmware options.

In addition to the Article No., the following firmware options can currently be ordered with or without perbance expansion:

  • Safety Integrated Extended Functions, order codes per axis F01 to F06 (see section Safety Integrated)
  • High output frequency 1), order code J01
  • DCB Extension, order code U01(further inbation about DCB Extension and license upgrades can be found under Drive Control Chart (DCC) in the section Engineering tools)

After the appropriate license has been purchased via the WEB License Manager available on the Internet, firmware options can also be subsequently enabled.


CU320‑2 Control Units feature the following interfaces as standard:

  • 4 DRIVE-CLiQ sockets for communication with other DRIVE-CLiQ devices, e.g. Motor Modules, Line Modules, Sensor Modules, Terminal Modules
  • CU320‑2 PN: 1 PROFINET interface with 2 ports (RJ45 sockets) with PROFIdrive V4 profile
  • CU320‑2 DP: 1 PROFIBUS interface with PROFIdrive V4 profile
  • 12 beterizable digital bs (floating)
  • 8 beterizable bidirectional digital bs/outputs (non-floating)
  • 1 serial RS232 interface
  • 1 interface for the BOP20 Basic Operator Panel
  • 1 slot for the CompactFlash card on which firmware and beters are stored
  • 1 slot for mounting an option module (e.g. TB30 Terminal Board)
  • CU320‑2 DP: 2 rotary coding switches for manually setting the PROFIBUS address
  • 1 Ethernet interface for commissioning and diagnostics
  • 3 test sockets and one reference ground for commissioning support
  • 1 connection for the electronics power supply via the 24 V DC supply connector
  • 1 PE/protective conductor connection
  • 1 ground connection

A shield connection for the signal cable shield of an option module is located on the CU320‑2 Control Unit.

The available slot is used to optionally expand the interfaces, for example, to include additional terminals or for communication purposes.

The status of the CU320‑2 Control Unit is indicated via multi-color LEDs.

As the firmware and beter settings are stored on a plug-in CompactFlash card, the Control Unit can be changed without the need for software tools.

The CU320‑2 Control Unit can be mounted on the side of the Line Module in booksize bat via brackets integrated in a Line Module. The CU320‑2 Control Unit can also be fixed to the wall of the control cabinet using the integrated fixing lugs. As the CU320‑2 Control Unit is not as deep as the Line Modules, suitable spacers are available to increase the depth of the CU320‑2 Control Unit to 270 mm (10.6 in).


DRIVE‑CLiQ components such as Motor Modules and Active Line Modules can be connected to a CU320‑2 Control Unit. The number of modules depends on the perbance required, including duty type and additional functions.

The BOP20 Basic Operator Panel can also be snapped onto the CU320‑2 Control Unit during operation to perb diagnostics.

The CU320‑2 Control Unit and other connected components are commissioned and diagnosed with the STARTER commissioning tool.

A CompactFlash card with firmware version V4.4 or higher is a mandatory requirement for operation of the CU320‑2 PN Control Unit.
A CompactFlash card with firmware version V4.3 or higher is a mandatory requirement for operation of the CU320‑2 DP Control Unit.

Connection example of a CU320‑2 Control Unit


CU320‑2 Control Unit

PROFINET
PROFIBUS

6SL3040-1MA01-0AA0
6SL3040-1MA00-0AA0

Current requirement, max.

At 24 V DC,
without taking account of digital outputs, expansion option slot and DRIVE-CLiQ supply

1.0 A

Conductor cross-section, max.

2.5 mm2

Fuse protection, max.

20 A

Digital bs

In accordance with IEC 61131‑2 Type 1

12 floating digital bs

8 bidirectional non-floating digital bs/digital outputs

  • Voltage

-3 ... +30 V

  • Low level (an open digital b is interpreted as "low")

-3 ... +5 V

  • High level

15 ... 30 V

  • Current consumption at 24 V DC, typ.

3.5 mA

  • Delay time of digital bs 1), approx.


  • L → H

5 μs

  • H → L

50 μs

  • Conductor cross-section, max.

1.5 mm2

Digital outputs

Sustained short-circuit strength

8 bidirectional non-floating digital bs/digital outputs

  • Voltage

24 V DC

  • Load current per digital output, max.

500 mA

  • Delay time 1), typ./max.


  • L → H

150 μs/400 μs

  • H → L

75 μs/100 μs

  • Conductor cross-section, max.

1.5 mm2

Power loss

24 W

PE connection

M5 screw

Ground connection

M5 screw

Dimensions


  • Width

50 mm (1.97 in)

  • Height

300 mm (11.81 in)

  • Depth

226 mm (8.90 in)

Weight, approx.

2.3 kg (5.07 lb)

Certificate of suitability

cULus



溫馨提示

  • 還沒找到想要的產(chǎn)品嗎? 立即發(fā)布采購(gòu)信息,讓供應(yīng)商主動(dòng)與您聯(lián)系!

免責(zé)聲明:所展示的信息由會(huì)員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé),機(jī)電之家網(wǎng)對(duì)此不承擔(dān)任何責(zé)任。機(jī)電之家網(wǎng)不涉及用戶間因交易而產(chǎn)生的法律關(guān)系及法律糾紛,糾紛由您自行協(xié)商解決。
友情提醒:本網(wǎng)站僅作為用戶尋找交易對(duì)象,就貨物和服務(wù)的交易進(jìn)行協(xié)商,以及獲取各類與貿(mào)易相關(guān)的服務(wù)信息的平臺(tái)。為避免產(chǎn)生購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。過低的價(jià)格、夸張的描述、私人銀行賬戶等都有可能是虛假信息,請(qǐng)采購(gòu)商謹(jǐn)慎對(duì)待,謹(jǐn)防欺詐,對(duì)于任何付款行為請(qǐng)您慎重抉擇!如您遇到欺詐等不誠(chéng)信行為,請(qǐng)您立即與機(jī)電之家網(wǎng)聯(lián)系,如查證屬實(shí),機(jī)電之家網(wǎng)會(huì)對(duì)該企業(yè)商鋪?zhàn)鲎N處理,但機(jī)電之家網(wǎng)不對(duì)您因此造成的損失承擔(dān)責(zé)任!
您也可以進(jìn)入“消費(fèi)者防騙指南”了解投訴及處理流程,我們將竭誠(chéng)為您服務(wù),感謝您對(duì)機(jī)電之家網(wǎng)的關(guān)注與支持!

在線詢盤/留言 請(qǐng)仔細(xì)填寫準(zhǔn)確及時(shí)的聯(lián)系到你

  • 您的姓名:*
  • 聯(lián)系手機(jī):*
  • 固話電話:
  • 聯(lián)系郵箱:
  • 所在單位:
  • 需求數(shù)量:*
  • 咨詢內(nèi)容:
  • 您要求廠家給您提供:
    規(guī)格型號(hào) 付款條件 產(chǎn)品目錄 最低訂貨量
    運(yùn)送資料 提供樣本 庫(kù)存情況 包裝材料

您是不是在找