產(chǎn)品詳情
6SL3120-2TE21-0AD0 無(wú)錫市
上海斌勤電氣技術(shù)有限公司專業(yè)從事西門子這個(gè)品牌已經(jīng)有10年。
在松江工業(yè)園區(qū)有一定的名聲
不要問(wèn)我有沒(méi)有 西門子常規(guī)的都現(xiàn)貨 支持上門提貨
有需要的新老顧客歡迎上門提貨談生意(老顧客注意公司地址更改)
上海斌勤電氣技術(shù)有限公司(西門子合作伙伴)
聯(lián)系人 :康 奎(業(yè)務(wù)經(jīng)理)發(fā)布(聯(lián)系我有優(yōu)惠福利哦)
地 址:上海市松江區(qū)三新北路1800弄(松江商務(wù)電子園區(qū))24號(hào)樓5005室.
技術(shù)規(guī)范
|
Double Motor Module in booksize bat 6SL3120-2TE... |
---|---|
DC b voltage (up to 2000 m (6562 ft) above sea level) |
510 ... 720 V DC |
Output frequency |
|
|
0 ... 650 Hz 1) 2) 3) |
|
0 ... 300 Hz 2) |
|
0 ... 600 Hz 2) 3) |
Electronics power supply |
24 V DC -15 %/+20 % |
Type of cooling |
Internal air cooling (power units with increased air cooling by built-in fan) |
Permissible ambient and coolant temperature (air) during operation for line-side components, Line Modules and Motor Modules |
0 ... 40 °C (32 ... 104 °F) without derating, |
Installation altitude |
Up to 1000 m (3281 ft) above sea level without derating, |
Declarations of conbity |
CE (Low-Voltage and EMC Directives) |
Certificate of suitability |
cULus |
Safety Integrated |
Safety Integrity Level 2 (SIL 2) according to IEC 61508, For further inbation, see section Safety Integrated. |
1) At rated output current (max. output frequency 1300 Hz for 62.5 μs current control cycle, 8 kHz pulse frequency, 60 % permissible output current).
2) Note the correlation between max. output frequency, pulse frequency and current derating. For further inbation, see section Configuration notes.
3) The output frequency is currently limited to 550 Hz. The specified values apply to systems with license for high output frequency. For further inbation, see section Control Units and https://support.industry.siemens.com/cs/document/104020669
DC b voltage 510 ... 720 V DC |
Double Motor Module in booksize bat |
||||
---|---|---|---|---|---|
Internal air cooling C type |
6SL3120-... |
– |
– |
– |
2TE21-8AC0 |
Internal air cooling D type |
6SL3120-... |
2TE13-0AD0 |
2TE15-0AD0 |
2TE21-0AD0 |
2TE21-8AD0 |
Output current |
|
|
|
|
|
|
A |
2 × 3 |
2 × 5 |
2 × 9 |
2 × 18 |
|
|
|
|
|
|
|
A |
– |
– |
– |
2 × 24 |
|
A |
2 × 4 |
2 × 6.7 |
2 × 12 |
2 × 24 |
|
A |
2 × 2.6 |
2 × 4.3 |
2 × 7.7 |
2 × 15.3 |
|
|
|
|
|
|
|
A |
– |
– |
– |
2 × 36 |
|
A |
2 × 9 |
2 × 15 |
2 × 27 |
2 × 54 |
Type rating 1) |
|
|
|
|
|
|
kW (hp) |
2 × 1.6 (1.5) |
2 × 2.7 (3) |
2 × 4.8 (5) |
2 × 9.7 (10) |
|
kW (hp) |
2 × 1.4 (1) |
2 × 2.3 (2.5) |
2 × 4.1 (5) |
2 × 8.2 (10) |
DC b current Id2) |
A |
7.2 |
12 |
22 |
43 |
Current carrying capacity |
|
|
|
|
|
|
A |
100 |
100 |
100 |
100 |
|
A |
20 |
20 |
20 |
20 |
DC b capacitance |
μF |
220 |
220 |
220 |
705 |
Current requirement At 24 V DC, max. |
A |
0.9 |
0.9 |
0.9 |
1.1 |
Power loss 4) typ. 5)/max. |
kW |
0.05/0.1 |
0.08/0.13 |
0.15/0.19 |
0.28/0.35 |
Cooling air requirement |
m3/s (ft3/s) |
0.009 (0.32) |
0.009 (0.32) |
0.009 (0.32) |
0.0155 (0.55) |
Sound pressure level LpA (1 m) |
dB |
<60 |
<60 |
<60 |
<60 |
Motor connection U2, V2, W2 |
|
2 × plug-in connector (X1, X2) 6), |
2 × plug-in connector (X1, X2) 6), |
2 × plug-in connector (X1, X2) 6), |
2 × plug-in connector (X1, X2) 6), |
PE connection |
|
M5 screw |
M5 screw |
M5 screw |
M5 screw |
Motor brake connection |
|
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Integrated into the plug-in motor connector (X1, X2), 24 V DC, 2 A |
Motor cable length, max. |
|
|
|
|
|
|
m (ft) |
50 (164) |
50 (164) |
50 (164) |
70 (230) |
|
m (ft) |
75 (246) |
75 (246) |
75 (246) |
100 (328) |
Degree of protection |
|
IP20 |
IP20 |
IP20 |
IP20 |
Dimensions |
|
|
|
|
|
|
mm (in) |
50 (1.97) |
50 (1.97) |
50 (1.97) |
100 (3.94) |
|
mm (in) |
380 (14.96) |
380 (14.96) |
380 (14.96) |
380 (14.96) |
|
mm (in) |
270 (10.63) |
270 (10.63) |
270 (10.63) |
270 (10.63) |
Weight, approx. |
kg (lb) |
4.7 (10.4) |
4.7 (10.4) |
4.7 (10.4) |
7.7 (17.0) |
1) Rated power of a typical standard asynchronous (induction) motor at 600 V DC b voltage.
2) Rated DC b current for dimensioning an external DC connection. For DC b current calculation for dimensioning the Line Module, see section Configuration notes.
3) If, due to a number of Line Modules and Motor Modules being mounted side-by-side, the current carrying capacity exceeds 20 A, an additional 24 V DC connection using a 24 V terminal adapter is required (max. cross-section 6 mm2, max. fuse protection 20 A).
4) Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.
5) At max. motor cable length 30 m (98.43 ft), pulse frequency 4 kHz and DC b voltage 540 ... 600 V.
6) Connector not included in scope of delivery, see Accessories.
6SL3120-2TE21-0AD0 無(wú)錫市